40 | Controls
6 720 813 643 (2018/04)
5.6 Service menu - AU Technical Settings
Accessing the AU Technical Settings menu
▶ Touch the symbol .
Display shows P4 Information.
▶ Touch symbols or to select AU Technical Settings menu.
▶ Touch the symbol .
Display shows Technical Settings menu (password input).
▶ Select the password (1886).
Authentication completed.
▶ Touch the symbol .
Access to installer exclusive menus.
• P0 - Min. Power
• P1 - Maximum Power
• P2 - Minimum Power
• UC - Combustion Auto Adjust
• P7 - Gas Type (LPG, NG)
• LM - Temperature Limited
• PE - Appliance Type
• PF - Bypass (On / Off)
• PA - Actuator Calibration
• RS - Recirculation Settings
• IC - ICC
LM Temperature Limited
Unlock the Temperature Limit
▶ Touch the symbol .
Display shows following menu.
– Unlocked
– Locked
The current selection is in green color.
▶ Touch symbols or to select Unlocked.
▶ Touch the symbol .
▶ Touch the symbol to return to main menu.