4.12 Connecting relay outputs
To operate locks or alarm systems, the AMC2 has eight relay outputs. The outputs will be
connected to the 3-pin pluggable screw connectors S5, S6, S10, S11, S17, S18, S22 and S23.
For more information on these connections, refer to
Connecting diagrams, page 45
.
Figure4.18: Location of the relay output connectors
By default, the relay outputs are connected as floating contacts (E1). However, it is possible
to connect the internal voltage 12/24 V of the AMC2 to each relay output (E2) to control
external consumers.
E 1:
E 2:
NO
NC
C
Figure4.19: Relay mode settings
E 1:
E 2:
1
2
5
6
7
8
2
34
34
7
8
5
6
Figure4.20: Location of relay output jumpers (bottom side)
E1 Delivery status