Access Modular Controller 2 Appendices | en 47
Bosch Security Systems B.V.
Guide d'installation
2022-11 | V04 |
1 Power supply, DC positive (10V - 30V)
2
Shield
3 Power supply (0V)
4 UPS (power good signal) - AC
5 UPS (power good signal) - Battery
6 UPS (power good signal) - DC
7 UPS (power good signal) - Common
Table11.6: Power supply
1 Reader Supply (10V - 30V)
2 Reader Supply (0V)
3
Shield
4 Data RxTx+
5 Data RxTx-
6 PAG
7 Not connected
8 Not connected
9 Not connected
10 Not connected
Table11.7: RS485 reader interface
i
Notice!
For reader settings refer to the respective reader manual.
1 Analog Input, in
2 Analog Input, out
Table11.8: Analog input
1 Relay Output, normally open
2 Relay Output, common
3 Relay Output, normally closed
Table11.9: Relay output