10.2 Range for heat pump without booster heater
In heating mode the heat pump switches off at approx. – 23 °C or +45 °C
outdoor temperature. The indoor unit or an external heat source then
takes over the heating and domestic hot water production. The heat
pump restarts if the outdoor temperature exceeds roughly – 17 °C or
falls below +42 °C.
In cooling mode, the heat pump switches off at roughly +45 °C and
restarts at roughly +42 °C.
Fig. 42 Heat pump in heating mode without booster heater
[1] Flow temperature (T0)
[2] Outdoor temperature (T1)
Fig. 43 Heat pump in cooling mode
[1] Flow temperature (T0)
[2] Outdoor temperature (T1)