ID Description
Advanced parameters
65= Primary DNS server address (IPv4 address format)
66= Alternate DNS server address (IPv4 address format)
67= Panel programming enabled
0 = disabled
1 = enabled
68= Reporting delay for low signal strength (0 - 3600 sec)
69= Reporting delay for no towers (0 - 3600 sec)
70= Reporting delay for single tower (0 - 3600 sec)
71= Modem reset count (0 – 99)
72= TCP keep alive time (0 – 255 sec)
Table 5.6: SMS configuration parameters
Multiple SMS Messages (for Messages Longer than 160 Characters)
ID
Description Sample SMS
1
%1; SMS sequence number 1
%1;1=B450;2=secret123;15=3;
16=010203040506070809101112131
41516;
1=B450; Current password
2=secret123; New password (case sensitive)
15=3; Enable AES encryption
16=01020304050607080910
111213141516;
Sample AES key
1
As you enter in the various ID’s into your cell phone, do not
press the return key. Doing so will cause the B450 to ignore
the programming request.
Table 5.7: Double SMS example, part 1
ID Description Sample SMS
2
%2; SMS sequence number
%2;19=1;!
19=1; Tamper enabled
! End of configuration
2
When you end the configuration programming with the
exclamation mark, do not enter any values. Doing so may
cause the B450 to ignore the programming request.
Table 5.8: Double SMS example, part 2
34 en | Configuration