Menu: Energy consump.
Table 25 Total energy consumption data
Menu: Energy consump. > Electric auxiliary heater
Table 26 Energy consumption data for electric booster heater
Menu: Energy consump. > Compressor
Table 27 Energy consumption data for heat pump
Menu: Energy supplied
Table 28 Energy output data for heat pump
Menu: Solar
Table 29 Information about the solar system
Menu: Outdoor temp
The currently measured outside temperature is displayed in this menu. In
addition, a diagram of the outside temperature profile for today and
yesterday (from 00:00 to 24:00 in each case) is displayed here.
Menu: Internet
Table 30 Information about the Internet connection
3.5 Faults
If a fault persists:
▶ Confirm the fault by pressing the selector.
▶ Faults that are still active are displayed by pressing the d key.
▶ Call an authorised contractor or customer service and give them the
fault code and sub-code, as well as the ID no. of the user interface.
Table 31 Your contractor must enter the ID no. here.
Faults on additional heat source:
▶ Check the display of the additional heat source for information.
▶ Reset the additional heat source.
▶ If the fault persists; contact your contractor.
4 Maintenance
DANGER
Risk of electric shock.
Grave personal injuries may occur.
▶ Disconnect the power supply before carrying out maintenance work.
Using the wrong cleaning product may damage the units!
▶ Do not use acid or chlorine based products or products that contain
abrasives.
4.1 Indoor unit
Check the following points a couple of times a year:
▶System pressure
▶ Particle filter
▶ Pressure gauge
▶ Moisture in cooling mode
▶Safety valves
Menu item Description
Total Cumulated total energy consumed by the heating
system.
Menu item Description
Total Cumulated total energy consumed by the electric
booster heater.
Heating Cumulated energy consumed by the electric booster
heater in heating mode.
DHW Cumulated energy consumed by the electric booster
heater in DHW mode.
Pool Cumulated energy consumed by the electric booster
heater in pool heating mode.
Menu item Description
Total Cumulated total energy consumed by the heat
pump.
Heating Cumulated energy consumed by the heat pump in
heating mode.
DHW Cumulated energy consumed by the heat pump in
DHW mode.
Cooling Cumulated energy consumed by the heat pump in
cooling mode.
Pool Cumulated energy consumed by the heat pump in
pool heating mode.
Menu item Description
Total energy
suppl.
Cumulated total energy output of the heat pump.
Heating energy
suppl.
Cumulated energy output of the heat pump in
heating mode.
DHW energy
suppl.
Cumulated energy output of the heat pump in DHW
mode.
Emitted cooling
energy
Cumulated energy output of the heat pump in
cooling mode.
Pool energy
suppl.
Cumulated energy output of the heat pump in pool
heating mode.
Menu item Description
Solar sensor
(graphic)
Current measured temperatures with display of
position of the selected temperature sensor in the
solar system hydraulics (with graphic visualisation
of the current operating conditions of the actuators
in the solar system).
Solar yield Solar yield for last week, solar yield for current week
and total yield of solar system since the solar system
was commissioned.
Menu item Description
IP connection Status of the connection between communication
module and router.
Server
connection
Status of the connection between communication
module and Internet (via the router).
Connected
network
Status of the connection between communication
module and the network and display of WLAN-SSID.
IP address IPV4 address of the communication module.
SW version Software version of the communication module.
Login data Login name and password for the login into the App
to operate the system via a smartphone.
MAC address MAC address of the communication module.
__ _