6 720 820 871 (2016/12) CR 400 | CW 400 | CW 800
32 | Working with the main menu
Menu: Holiday 1, Holiday 2, Holiday 3, Holiday 4 and Holiday 5
Menu item Description
Holiday
period
Set the start and end date of the absence
during holiday: the holiday program starts at
the set start time at 00:00. The holiday
program ends at the set end time at 24:00
o'clock.
Selection
heat. circ./
DHW
The holiday program is applied to the
sections of the system highlighted here.
Only the heating circuits and DHW systems
actually installed in the system are available
for selection. Heating circuits to which an
CR100 user interface is assigned as a
remote control are not displayed. The
holiday program must be set on each remote
control separately.
Heating Control of the room temperature for the
selected heating circuits during the holiday
period:
• With As Saturday, the heating system
runs in the selected heating circuits
every day in accordance with the time
program that is active for Saturday
(holiday at home).
•A Constant temperature can be
selected at will to be valid for the
selected heating circuits throughout the
entire holiday period.
• The Off setting deactivates the heating
system completely for the selected
heating circuits.
• With the Setback setting, the heating
system runs in the selected heating
circuits in the operating mode set by the
contractor in each case (Reduced
mode, Outside temperature
threshold, Room temperature
threshold starting on page 42).
Table 28 Settings for holiday programs
DHW DHW settings for the selected DHW systems
during the holiday period.
• If Off is set, no DHW at all will be
available during the holiday period.
• If Off + therm. disinfection on is set,
DHW heating is deactivated but thermal
disinfection is still carried out as normal
either once a week or once a day.
Note: If the holiday is spent at home, the
DHW systems must not be selected under
Selection heat. circ./DHW to ensure DHW
remains available.
Delete Delete all settings for the selected holiday
program
Menu item Description
Table 28 Settings for holiday programs