D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 18.0 Installer Menu
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 115
DHCP/AutoIP Enable
B91x/B92x keypads Configuration of DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [2] Network > [1] Bus Module (1) or [2] Bus Module (2) > [1]
Module Parameter > [1] DHCP menu option. The keypad displays the DHCP/AutoIP current
configuration
3. Press [ENTER] to edit the DHCP/AutoIP Enable configuration for the module.
4. Use the [PREV] or [NEXT] key to toggle between between Yes and No.
5. Press [ENTER] while viewing the desired option to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [2] Network > [1] Bus Module (1) or [2] Bus Module (2)> [1]
Module Parameter > [1] DHCP menu option. The keypad displays the DHCP/AutoIP current
configuration.
3. Press the Yes or No softkey – whichever is available – to change the programming.
4. Press the Save softkey to save the programming.
5. When the keypad shows Parameter Saved, escape from the menu.
UPnP Enable
B91x/B92x keypads Configuration of UPnP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [2] Network > [1] Bus Module (1) or [2] Bus Module (2) > [1]
Module Parameter > [2] UPnP menu option. The keypad displays the UPnP current
configuration.
3. Press [ENTER] to edit the UPnP Enable configuration for the module.
4. Use the [PREV] or [NEXT] key to toggle between between Yes and No.
5. Press [ENTER] while viewing the desired option to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of UPnP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [2] Network > [1] Bus Module (1) or [2] Bus Module (2) > [1]
Module Parameter > [2] UPnP menu option. The keypad displays the UPnP current
configuration.
3. Press the Yes or No softkey – whichever is available – to change the programming.
4. Press the Save softkey to save the programming.
5. When the keypad shows Parameter Saved, escape from the menu.