D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 8.0 On-Board Points
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 44
Figure 13: Rothenbuhler 5110/4001-42 High Security Bell Wiring Configuration
1 - Self-contained vibration sensor
2 - Control panel
3 - Accessory modules
4 - High line security module
5 - 4001-42 Balanced Line Module
6 - 5110 Bell
7 - D133 Relay
8 - Alarm zone input
1
9 - D122/D122L Battery Harness
2
10 - D126 Battery
11 - D8108A Enclosure
12 - D122/D122L Battery Harness
2
13 - Proximity/control unit
14 - Normally open (NO)
15 - Normally closed (NC)
16 - End-of-line (EOL) resistor
17 - Safe
1
Use Terminal 11, 13, 14, 17, 19, 20, or 22. (Select only one.)
2
Use a D113 Battery Lead Supervision Module to supervise the battery connections.
0.64 mm (1/4 in.)
minimum distance
+
-
+
-
17
3
14
16
15
4
7
5
8
12
13
1
1
11
11
9
2
6
10
10

Table of Contents