Model | FPA-1200-MPC |
---|---|
Power Supply | 24 V DC |
Event Log | Up to 10, 000 events |
Operating Temperature | 32°F to 120°F (0°C to 49°C) |
Type | Modular Fire Panel |
Communication | Ethernet, RS-485 |
Weight | Approx. 8 kg |
NAC Outputs | 2 outputs |
Programmable Relays | 3 |
Humidity Range | 0 to 93% RH, non-condensing |
Explains how to interpret step-by-step instructions and symbols.
Instructions on accessing the main menu using the 'home' key.
Procedure to change the panel's display language via shortcut or menu.
Details exclusions and conditions for warranty claims.
Information on documentation copyright and rights to make changes.
Explanation of warning, caution, and information symbols in the manual.
Guidelines for safe and proper operation of the touch-sensitive display.
Instructions for cleaning the touch screen and membrane keypad.
Overview of tasks the panel controller can perform.
Specifies that trained and authorized personnel are required for operation.
Instructions on how to return to the start menu from any submenu.
Overview of functions for bypassing and isolating system elements.
Overview of diagnostic options for modules, hardware, and panel.
Overview of maintenance tasks including walktest, language, and outputs.
Procedure to change the display language.
Steps for activating various system outputs.
Procedure to activate a selected transmission unit.
Steps for bypassing devices during detector removal.
Using filters to view and print event data.
Procedure to assign a different device to the V.24 interface.
Overview of system configuration options.
How to switch between day and night operational modes.
Accessing functions like date/time, password, and fire drill.
Tools for searching system functions and elements.
Procedures for resetting system elements to their initial state.
Description of function keys, alphanumeric keypad, and home key.
Explanation of LED indicators and their meanings.
Details of the touch screen interface layout and navigation.
Information shown on the panel when it is in standby mode.
Procedure to display support service contact information.
Procedures for user login and logout to access system functions.
Steps to log out of the panel controller.
Explanation of user access levels and permissions.
Instructions on how to return to the start menu from any submenu.
How to navigate and select menus and submenus on the touch screen.
How to use the 'Back' key to navigate to the previous screen.
General methods for navigating and interacting with displayed lists.
Methods for scrolling up, down, and rapidly through list items.
Interpretation of different visual states in list fields.
How to select individual elements or functions from a list.
How to assign modes like Bypassed or Walktest to elements.
Overview of the system's search capabilities.
How to search for elements using their numbers.
Key assignments for entering characters on the keypad.
How to modify existing entries in search screens.
Procedure to clear all entered numbers in a search screen.
Methods for selecting a different display language.
How to navigate between different status bars.
Understanding the distinction between logical and physical addressing.
Explanation of icons used to represent network connections.
How network addresses (node ID, group ID) are assigned.
Steps to connect to a networked panel from another panel.
How to disconnect from a previously established remote connection.
Understanding isolating and restricted connection types.
Prerequisites and interpretation of the remote keypad's operation and display.
Classification of different alarm types like Fire, Heat, Smoke, Water, Supervisory.
Explanation of alarm delay strategies to prevent false alarms.
How day/night modes affect alarm handling and security levels.
Details of how alarms are presented on the panel, including signals and display.
How alarm messages are ordered and displayed chronologically.
Details provided for logical zones when in an alarm state.
How the latest alarm message is presented in the list.
How to view individual detectors within a logical zone during an alarm.
Data points included for each individual detector alarm.
Accessing extra details for alarm messages.
How fire alarms are signaled visually and audibly on the panel.
Procedures for acknowledging alarm messages on the panel.
How to temporarily silence the internal alarm buzzer.
Managing external sirens and strobes (on/off).
Steps to reset external signaling and transmission devices.
How to initiate and manage fire alarm verification procedures.
How to manually trigger an alarm to be forwarded.
Steps to reset alarm messages after they have been handled.
Procedure to bypass detectors that have triggered an alarm.
How to access and display fault messages on the panel.
How trouble messages are displayed, acknowledged, and sequenced.
How the latest fault message is displayed in the list.
How to view individual elements within a fault group.
Details provided for individual element fault messages.
Accessing extra details for fault messages.
Explanation of fault signal lights and sounds.
Procedures for resetting malfunction messages.
How to isolate elements that have caused a fault.
Overview of the bypass menu structure and options.
Steps to bypass and un-bypass individual elements.
Managing bypassed element groups and their statuses.
How to view lists of all bypassed elements.
Accessing bypassed element lists via the status bar.
Permanently bypassing the panel's internal buzzer.
Overview of the isolate menu structure and options.
Steps to isolate and de-isolate individual elements.
How to view lists of all isolated elements.
Overview of the diagnostics menu and its sections.
Displaying diagnostic information for modules and elements.
Displaying diagnostic information for modules.
Diagnostic information for hardware components.
Displaying statistical data for data transmission.
Displaying the status of CAN interfaces.
Displaying diagnostic information about the panel controller.
Testing the LED displays on system modules.
Information on network nodes and interfaces.
Diagnostic information for connected voice alarm systems.
Overview of the maintenance menu and its options.
Procedure to change the panel's display language.
Steps for activating various system outputs.
Procedure to activate a selected transmission unit.
Procedures for detector removal and temporary bypass.
Procedure to assign devices to the V.24 interface.
Permanently bypassing the panel's internal buzzer.
How to create and manage walktest groups for testing elements.
How to add or remove elements from walktest groups.
Procedures for starting and ending walktests for groups or elements.
How to end a specific walktest group.
Procedures to end all walktests across the system.
Viewing the status of elements tested or not tested.
How to move tested elements to a different walktest group for future use.
Overview of available filters for the history log.
How to apply filters to view specific data in the history log.
How to modify or change existing filters in the history log.
Applying multiple filters simultaneously to the history log.
Functions available via the status bar for filter management.
How to print history log data, either fully or partially.
How to change the panel's operational mode between day and night.
Viewing details of logical zones switched to day mode.
Adjusting the time for automatic reset to night mode.
Overview of the configuration menu and its sections.
Creating and managing input/output groups for detectors and devices.
How to rename input or output groups.
Overview of bypass, isolate, and walktest group settings.
Adjusting detector sensitivity settings.
Managing operator access levels and passwords.
Resetting operator passwords to their previous or default sequence.
Changing the names of system elements.
Displaying system configuration details.
Overview of the 'Further functions' menu.
How to change the system's date and time settings.
Information on master password types and access procedures.
Procedure for entering an indefinite master password.
Steps to obtain and use a temporary 24-hour master password.
Establishing teleservice connections to the system.
How operators can change their passwords.
Procedures for initiating and managing fire drills.
Displaying and resetting alarm message counters.
Overview of the reset menu and its options.
Steps to reset detectors or logical zones to their initial state.
Overview of the search menu.
How to search for system functions and device descriptions.