EasyManua.ls Logo

Bosch Greenstar combi 151 p - Condensate Composition; 4 Regulations; Compliance with Standards and Regulations

Bosch Greenstar combi 151 p
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Regulations | 13
6720872361 (2017/04)Greenstar combi 100 p / 151 p
Table 4 Technical data ZWB42-3A...
3.10 Condensate composition
The condensate volume and ingredients may change with regionally and
seasonally varying gas quality and air quality. Typically the following
ingredients and concentrations can be expected:
Table 5 Typical condensate composition
4 Regulations
Observe all rules, regulations, standards and guidelines applicable to the
installation and operation of this appliance in your country.
Valves external to the boiler must be fitted with T-handles and
condensate piping must be installed in accordance with the State
Plumbing Code.
4.1 Compliance with standards and regulations
The installation must conform to the requirements of the authority
having jurisdiction or, in the absence of such requirements, to the latest
edition of the National Fuel Gas Code, ANSI Z223.1./NFPA 54. In
Canada, installation must be in accordance with the requirements of
CAN/CSA B149.1, Natural Gas and Propane Installation Code.
This wall-mounted condensing gas boiler complies in its design and
mode of operation with the American National Standard ANSI Z21.13/
CSA4.9, latest edition for Gas-Fired Low-Pressure Steam and Hot Water
Boilers.
Other confirmed approvals and certifications are indicated by labels on
the boiler.
If so advised by the responsible agency, the installation must satisfy the
requirements of the standard for Controls and Safety Devices for.
Automatically Fired Boilers, ANSI/ASME CSD-1.
Install CO detectors per local regulations. Wall-mounted gas condensing
boilers require yearly maintenance ( Chapter 14, page 48).
General
Voltage VAC 120 120
Frequency Hz 60 60
Max. power consumption (central heating mode) W 205 205
Max. power consumption (Stand-by) W < 6 < 6
Sound pressure level dB(A) 45 45
Max. supply temperature °F ( °C) 187 (86) 187 (86)
Max. permissible operating pressure (P
MS
) heating psi (bar) 30 (2.07) 30 (2.07)
Permissible ambient temperature °F ( °C) 32 - 122 (0 - 50) 32 - 122 (0 - 50)
Nominal water capacity (heating) gal (l) 0.925 (3.5) 0.925 (3.5)
Weight (without packaging) lbs. (kg) 110.2 (48) 110.2 (48)
Dimensions, W x H x D inch
(mm)
17-21/64" × 33-15/32" × 13-57/64"
(440 × 850 × 353)
Greenstar combi 151 p, ZWB42-3A...
Unit NG LPG (propane)
Substance Value in ppm (mg/l)
Ammonium 1.2
Lead  0.01
Cadmium  0.001
Chrome  0.005
Halogenated hydrocarbons  0.002
Hydrocarbons 0.015
Copper 0.028
Nickel  0.1
Mercury  0.0001
Sulfate 1
Zinc  0.015
Tin  0.01
Vanadium  0.001
pH-value 4.8