22 | Notes on installation and operation
Greenstar combi 100 p / 151 p6720872361 (2017/04)
Fig. 14 Hydraulics connection plate (top view)
Determine pipe size for the gas supply.
To fill and drain the system, install a fill and drain valve at the lowest
point.
6.5 Mounting the appliance
NOTICE:
Residue, metal shavings, and contaminants in the piping can
damage the appliance.
Flush the piping thoroughly and completely to remove all residue.
Follow the instructions with respect to water quality (
Chapter 6.1.1, page 19).
Remove packaging, observing all notes and symbols.
On the type plate, check the identification of the target country and
suitability for the gas type supplied by the local gas utility company
( page 8).
Removing the cover
The cover is secured with two screws against unintentional removal
(electrical safety).
Always keep the cover secured with these screws.
Undo screws (step 1).
Lift strap (step 2) and remove cover toward the front (step 3).
Fig. 15 Remove the cover
Hanging the appliance
Check that the gas type matches ( data plate).
Remove the transport brackets.
Place the gaskets on the pipe connections.
Hang the appliance.
Check the positioning of the gaskets on the pipe connections.
Tighten the union nuts on the pipe connections.
==
1 31/32
"
(50 mm)
5 1/8
"
(130 mm)
10 15/64
"
(260 mm)
1 3/8
"
(35 mm)
6 720 641 933-14.1O
1
3
6 720 641 933-96.2O
1
2