Working
with
the
main
menu
BOSCH
~
If
the
standard
display
is
active
,
press
the
DHW
key
.
~
:~~--~
[liiiiiiiiiiiiiiiiiiiiiiiii
••
iJ
l
~
Turn
the
selector
to
highlight
Always
on
-
DHW
red
.
or
Always
on
-
DHW
.
~
Press
the
selector
. 0
Always
on
CHW
red.
I
DHW
heating
is
active
uninterrupted
. 1,1
:::,
.
-::A~lw
~
ays::--on_,_c_
H
W
____
...J1
AI
0
Own
time
pro~
ways
on
-
DHW
will
result
in
a
higher
energy
consumption
and
sound
level
than
Alway
s
on
-
DHW
red
..
Select operatlnr mode (or
OHW
system,
Table
19
Adapting
the
settings
for
DHW
heating
5.3
.3
Ext
ra
DHW
heatin
g
This
menu
allows
you
to
set
how
DHW
heating
operates
when
the
extra
DHW
funct
i
on
is
activated
.
Menu
:
Extra
hot
water
Menu
Item
d
escn
ption
This
menu
item
enables
the
extra
DHW
function
to
be
started
and
cancelled
.
Its
function
is
the
same
as
the
extra
DHW
key
.
When
the
extra
DHW
function
is
act
i
ve,
the
DHW
is
heated
to
the
temperature
set
here
.
The
extra
DHW
function
switches
off
'--
____
~
au
_
t
.:...
om
....
atically
after
the
set
time
.
Table
20
Extra
DHW
heating
settings
5.
3.4
Thermal
dis
infecti
on
Following
thermal
disinfection
,
the
cylinder
content
slowly
cools
back
down
to
the
set
DHW
temperature
.
The
cool
down
is
effectuated
mainly
through
heat
losses
.
Consequently,
the
DHW
temperature
may
briefly
be
higher
than
the
selected
temperature
.
&
CAUTION
:
Legionnaire
's
bacteria
c
onstitute
a
I
health
hazard!
...
At
low
hot
water
temperatures
thermal
disinfection
or
daily
heating
should
be
activated
1
)
(-7
note
the
drinking
water
statute)
.
1)
Daily
heating
can
be
set
by
your
installer
in
the
service
menu
.
&
6 7
20
8
11
136-28.
10
WARNING
:
Risk
of
scalding
!
If
thermal
disinfection
has
been
activated
to
avoid
legionella,
the
hot
water
is
heated
once
to
in
excess
of
65
·C
(e
.g.
Thursday
night
at
02:00).
~
Only
schedule
thermal
disinfection
for
periods
ou
tside
normal
usage
times
.
~
Make
sure
thata
mh
i
er
is
i
nstalled
. lfin
doubt
,
ask
your
contractor
.
The
thermal
disinfection
safeguards
the
hygienic
quality
of
the
DHW
.
The
hot
water
is
heated
regularly
to
the
set
temperature
.
This
also
kills
off
leg
i
onella
,
for
example
.
Thermal
disinfect
i
on
can
be
configured
in
this
menu
.
Menu
:
Thermal
disinfection
Menu
item
d
es
cri
ptio
n
Start
Start
now
/
cancel
I
The
entire
DHW
volume
is
on
ly
heated
to
the
set
temperature
once
a
week
or
once
a
day
if
Auto
is
set
here
.
I
Immediate
start
or
termination
of
the
thermal
disinfection
i
ndependent
from
the
1-1
____
-+-1 s_
et
_
day
of
the
week
Temperature
Temperature
of
the
entire
DHW
volume
at
Day
thermal
disinfection
(65
...
80
OC)
The
day
on
which
thermal
disinfection
is
I
performed
.
Time
of
day
Time
of
dayfortheautomaticstartofthermal
I
disinfection
Max
.
period
If
the
thermal
disinfection
temperature
is
not
reached
within
the
time
set
here
.
thermal
disinfection
is
cancelled
.
The
user
interface
then
issues
a
fault
in
the
display
.
Table
21
Settings
for
the
thermal
disinfection
22
,
HPC
400 - 6
720821983
(2017/07)
'f
,
l
{}
BOSCH
5.3.5
DHW
alternating
operat
i
on
setti
ngs
In
DHW
alternating
operation
,
DHW
and
heating
have
equal
priority
and
alternate
based
on
time
. A
heat
requirement
from
the
heating
system
is
nottaken
into
account
while
DHW
heating
is
active,
and
vice
versa
.
If
DHW
alternating
operation
is
not
active
,
DHW
heating
has
priority
and
interrupts
the
heat
requirement
of
the
heating
system
,
if
necessary
.
Menu
:
DHW
alternating
operat
i
on
oper.
on
In
the
event
of
a
simultaneous
heat
energy
demand,
the
system
will
alternate
between
DHW
heating
and
heating
mode
based
on
the
times
set
under
DHW
priority for
and
PriorItlse
heating
for.
DHW
priority
DuratlQ.n
of
DHW
heating
for
DHW
altern.
for
oper
.
on
.
I
Priorlti
se
I Du
ration
of
heating
mode
for
DHW
altern.
heating
for
oper
.
on
.
Table
22
DHWaltemating
operation
settings
5.3.6 Setti
ngs
for
DHW
circulation
A
DHW
circulation
pump
circulates
DHW
between
the
DHW
heater
and
the
draw
·
off
point
(e
.g.
water
tap)
.
This
makes
DHW
available
at
the
draw
·off
point
more
quickly
.
This
menu
is
only
avai
l
able
for
systems
with
DHW
circulation
pump
.
Menu
: Circulation
1
)
Settings
can
be
made
determining
when
and
how
often
the
DHW
circulation
pump
is
activated
.
1)
Not
available
if
Sweden
or
Finland
is
set
as
the
country
(for
the
contractor
only)
.
In
these
countries
the
DHW
circulation
pump
will
run
continuously
without
time
c
ontrol.
Working
with
the
main
menu
Menu
item
description
Operating
mode
Start
frequency
MyDHW
clrcltntime
prog
.
Circulation
can
be
sw
i
tched
off
permanently
(Off).
If
this
setting
is
set
to
On
,
the
pump
will
run
according
to
the
settings
under
Start
frequency
.
The
time
program
for
the
DHW
circula
t
ion
pu
mp
is
not
active.
Circulation
can
be
linked
to
the
time
program
for
DHW
heating
(
As
hot
water
system
).
With
Own
time
program
a
time
program
for
the
DHW
circulation
pump
can
be
set
that
works
independently
of
the
time
program
for
DHW
.
The
start
frequency
determines
how
often
the
DHW
circulation
pump
goes
i
nto
operation
for
I
three
minutes
at
a
time
every
hour
(1
x
3
minutes/h
...
6 x 3
minutes/h)
or
if it is
consta~t
l
y
in
operation.
Whatever
the
case
,
Ci
rcu
l
ation
IS
on
ly
active
during
the
ti
m
es
set
in
the
time
program
.
6
switching
times
can
be
set
for
each
day
or
1
groupof
days
.
The
DHW
circulation
pump
can
be
SWitched
on
or
off
at
each
switching
time
.
The
minimum
d
.
urati~n
of
a
time
sl
ot
between
j
two
SWitching
ti
mes
IS
15
minutes
.
Table
23
Settings
for
the
ci
rculation
HPC
400 - 6
720821983
(2017/07)
23