Installation Instructions
Bosch IDS BOVA20 & BOVC20 Split System Heat Pump - BTC 761703109 A (12.2023)
10 |
6 Refrigerant Line Routing
6.1 Precautions
Take precautions to prevent noise within the building structure due to
vibration transmission from the refrigerant lines. For example:
• When the refrigerant lines have to be fastened to floor joists or
other framing in a structure, use isolation type hangers.
• Isolation hangers should also be used when refrigerant lines are
run in stud spaces or enclosed ceilings.
• Where the refrigerant lines run through a wall or sill, they should
be insulated and isolated.
• Isolate the lines from all ductwork.
• Minimize the number of 90º turns.
Figure 11
Side View
8 Feet Maximum
8 Feet Maximum
Joist/Rafter
Isolator
Lineset
Secure Suction Line from joists using isolators every 8 ft. Secure Liquid Line
directly to Suction Line using tape, wire, or other appropriate method every 8 ft.
Isolation From Joist/Rafter
Figure 12
Secure SuctionLineusing isolatorsevery 8 ft . Secure Liquid Line
directly to SuctionLineusing tape,wire, or otherappropriate
method every8 ft.
Side View
8 Feet Maximum
8 Feet Maximum
Wall
Isolator
Linesets
Secure Suction Line using isolators every 8 ft. Secure Liquid Line directly to
Suction Line using tape, wire, or other appropriate method every 8 ft.
Isolation On Walls
  Comply with National, State, and local codes when isolating linesets
from joists, rafters, walls, or other structural elements.