Mounting the camera module
Mounting flush to ceiling
To mount the camera flush to the ceiling:
1. Mark out the recess hole and the three mounting holes. The
mounting holes are equally spaced around a diameter of
133 mm (5.25 in).
2. Cut out the inner recess hole: Ø105 mm (4.13 in).
3. Use a 8 mm (0.31 in) bit to drill the three mounting holes
4. Insert the supplied mounting plugs (8 x 40) into the
mounting holes.
5. Use the supplied screws (DIN7505-B 50mm) to securely
mount the camera to the ceiling surface; if the ceiling is too
thin, use appropriate ceiling bolts (not supplied).
57.6 (2.27) 57.6 (2.27)
33.3 (1.31)
66.5 (2.62)
Ø
133 (
Ø
5.25)
mm (in)