EasyManua.ls Logo

Bosch PVA-4CR12 - Analog Control in

Bosch PVA-4CR12
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ANALOG CONTROL IN
The upper half of the control port has eight freely programmable control inputs for voltages of
between 0 volts and 10 volts. The inputs are numbered 1 through 8. The controller provides
its own voltage supply for externally connected control elements, e.g., a potentiometer. The
voltage supply is available at the control port connections for 10V REF and ground; see the
following diagram.
Figure 6.10: Sample application of a control input and use of an analog input signal
The control inputs can also be used as digital control inputs. Internally, the control inputs are
connected to ground via a resistor. If an input is connected to the 10 V REF pin or another,
external voltage, the input switches to the active status (On).
!
Caution!
The maximum permissible voltage on a control input is 32 V.
6.10.2
PAVIRO Controller Connection | en 31
Operation manual 08-May-2017 | 04 | F01U306900