7.4.8 Changing the lever position of the HW control
If necessary, you can change the position of the lever by turning.
Required tools: Hexagon socket wrench with WAF 4mm.
1. Loosen and remove the mounting bolt (1) of the HW lever (2).
2. Pull the HW lever up, turn it into the desired position and push it back down.
3. Tighten the mounting bolt(1) again.
Tightening torque M
A
=6.5Nm.
1
2
1
2
Fig. 12: Changing the lever position of the HW control
7.4.9 Changing the lever position of the DA control valve (size 28 to 63)
If necessary, you can change the position of the lever by turning.
Required tools: Hexagon socket wrench with WAF 4mm.
1. Loosen the clamping screw(1) of the DA lever(2).
2. Turn the DA lever to the desired position.
3. Tighten the clamping screw(1) again.
Tightening torque M
A
=5.2Nm.
1
2
Fig. 13: Changing the lever position of the DA control valve