Installation 43/64
RE 92750-01-B/06.2018, A10VG, Series 10, Bosch Rexroth AG
Table 10: Ports A10VG series 10
Ports
1)
Size
p
max
[bar]
2)
State
3)
A, B Working port 350 O
S Suction port 5 O
4)
T
1
Drain port 3 O
5)
T
2
Drain port 3 X
5)
R Air bleed port 3 X
X
1
, X
2
Control pressure port (upstream of
orifice)
Size 18
Sizes 28, 45, 63
25
40
X
G Boost pressure port inlet Size 18
Sizes 28, 45, 63
25
40
X
6)
P
S
Pilot pressure port Size 18
Sizes 28, 45, 63
25
40
X
M
A
, M
B
A, B measuring port pressure 350 X
M
H
7)
Measuring port, high pressure Size 63 350 X
F
a
Boost pressure port inlet Size 63 40 X
8)
F
e
Boost pressure port outlet Sizes 28, 45, 63 40 X
8)
Y
1
, Y
2
Pilot pressure port
(pilot signal HD only)
40 O
1)
The measuring system and thread size can be found in the installation drawing.
2)
Momentary pressure peaks may occur depending on the application. Keep this in mind when
selecting measuring devices and fittings.
3)
O = Must be connected (plugged when delivered)
X = Plugged (in normal operation)
4)
Plugged for external boost pressure supply (size 28 to 63).
5
Depending on the installation position, T
1
or T
2
must be connected (see chapter7.3 “Installation
position” on page31)
6)
For size 28 and 45, portG serves as “boost pressure port inlet F
a
” and must be connected for
filtration in the pressure line.
7)
Only available on version with pressure cut-off.
8
Must be connected for filtration in the pressure line.
The following tightening torques apply:
• Fittings:
Observe the manufacturer's specifications regarding the tightening torques of the
fittings used.
• Female threads in the axial piston unit:
The max. permissible tightening torques M
Gmax
are the maximum values for the
female threads and should not be exceeded. For values, see Table 11.
• Threaded plugs:
For the metallic threaded plugs supplied with the axial piston unit, the required
tightening torques of threaded plugs M
V
apply. For values, see Table 11.
• Mounting bolts:
For mounting bolts with DIN 13 metric ISO threads or ASME B1.1 threads, we
recommend checking the tightening torque in individual cases in accordance with
VDI2230.
Tightening torques