Installation 31/64
RE 92511-01-B/2019-10-09, A15V(L)O Series 11, Bosch Rexroth AG
Table 10: Inside-reservoir installation
Installation position Air bleed Filling
4 (drive shaft horizontal) T
1
the housing of the axial piston
unit is to be filled using T
1
before
attachment of the piping
5 (drive shaft vertically up) T
2
the housing of the axial piston
unit is to be filled using T
2
before
attachment of the piping
7.3.3 Above-reservoir installation
Above-reservoir installation means that the axial piston unit is installed above the
minimum fluid level of the reservoir.
To prevent the axial piston unit from draining, a height difference h
ES min
of at least
25mm at portT
2
is required in installation position 7.
Observe the maximum permissible suction height h
S max
= 800mm.
Thepermissible suction height h
S
is derived from the total pressure loss.
6 7
h
t min
h
min
h
S max
SB
F
T
1
T
2
T
3
S
h
ES min
SB
h
t min
F
h
min
h
S max
T
1
T
2
T
3
S
Fig. 11: Above-reservoir installation A15VO/A15VLO with installation position 6–7
T
1
,
T
2
,
T
3
Drain port h
t min
Minimum required immersion depth
(200mm)
F Filling/air bleeding h
min
Minimum required distance to
reservoir bottom (100mm)
S Suction port h
ES min
Minimum height required to prevent
axial piston unit from draining
(25mm)
SB Baffle (baffle plate) h
S max
Maximum permissible suction height
(800mm)
Port F is part of the external piping and must be provided on the customer side
to make filling and air bleeding easier.
Table 11: Above-reservoir installation
Installation position Air bleed Filling
6 (drive shaft horizontal) F T
1
(F)
7 (drive shaft vertically up) F T
2
(F)