Installation 45/64
RE 92511-01-B/2019-10-09, A15V(L)O Series 11, Bosch Rexroth AG
Exact details on the connector, type of protection and matching mating connector
can also be found in datasheet92511. The mating connector is not included in the
scope of delivery.
1. Switch off the power supply to the relevant machine/system part.
2. Electrically connect the axial piston unit (12 or 24 V). Before establishing the
connection, check whether the connector protective covers have been removed
and the connector and all seals are intact.
If necessary, you can change the position of the connector by turning the solenoid
body. This is independent of the connector version.
CAUTION! Hot surfaces on the solenoid!
Risk of burning!
▶ Allow the solenoid to cool down sufficiently before touching it.
▶ Protect yourself with heat-resistant protective clothing, e.g.gloves.
To do this, proceed as follows:
1. Loosen the mounting nut (1) of the solenoid. To do this, turn the mounting nut
(1) one turn counter-clockwise.
2. Turn the solenoid body (2) to the desired position.
3. Re-tighten the mounting nut. Tightening torque of the mounting nut: 5+1 Nm.
7.5 Performing flushing cycle
In order to remove foreign particles from the system, BoschRexroth recommends
a flushing cycle for the hydraulic system before the first commissioning. To avoid
internal contamination, do not include the axial piston unit in the flushing cycle.
Use an additional flushing unit to perform the flushing cycle. Follow the
instructions of the flushing unit's manufacturer for the exact procedure during the
flushing cycle.
Changing connector
position
1
2