Installation 37/64
RE 92511-01-B/2019-10-09, A15V(L)O Series 11, Bosch Rexroth AG
Important for LRDRS. controllers! Port X is equipped with a protective plug (3).
This portmust be connected. Failure to do so could lead to malfunctions or
damage.
You will find other ports for the respective control in the datasheet92511.
Setting screws are protected against unauthorized adjustment by tamper-proof
caps. Removal of the tamper-proof caps will void the warranty. If you need to
change the settings, please contact your local contact person; you can find their
contact information at
www.boschrexroth.com/addresses
3. For versions with through drive, install the auxiliary pump according to the pump
manufacturer's instructions. The protective cover (5) is not pressure-resistant and
should not be used during operation.
If the axial piston unit is to be operated without through drive unit, it has
to be closed by means of a pressure-tight cover before the commissioning!
Forquestions regarding conversions, contact your proper BoschRexroth service
partner or the service department of the plant that manufactured the axial piston
unit; seechapter 10.5 "Spare parts" on page 53.
7.4.8 Hydraulically connecting the axial piston unit
WARNING
Excessive control pressure for controllers with external control!
The pressurization of a control valve to above the permissible maximum pressure at
portX, e.g.DG setting, causes an impermissible pressure increase!
▶ Make sure that the permissible external pilot pressure, e.g.viaa pressure relief
valve, is not exceeded (seealso datasheet92510 DG controller technical data).