Technical data 11/68
Hägglunds VI, RE 15310-WA/10.2015, Intallation and maintenance manual, Bosch Rexroth Mellansel AB
Viscosity limits
Viscosity index
=100 recommended
=150* for operation with large
temperature dierence
Min. permitted in continuous duty
Min. permitted in intermittent duty
Max. permitted
40 cSt/187 SSU
20 cSt/98 SSU**
10000 cSt/48000 SSU
* Many hydraulic uids with VI-improvers are subject to temporary and permanent reductions
of the viscosity.
** Low viscosity gives reduced service life for the motors and reduction of max. allowed
power for “Hägglunds VI”.
Fire resistant uids
Operating with re resistant uids
The following uids are tested for Hägglunds motors: (ISO/DP 6071)
Fluid Approved Seals Internal paint
HFA: Oil (3-5%) in water emulsion No – –
HFB: Inverted emulsion 40-45% water in oil Yes Nitrile (std motor) Not painted*
HFC: Water-glycol Yes Nitrile (std motor) Not painted*
HFD synthetic uids
HFD:R – Phosphate esters Yes Viton Not painted*
HFD:S – Chlorinated hydrocarbons Yes Viton Not painted*
HFD:T – Mixture of the above Yes Viton Not painted*
HFD:U – Other compositions Yes Viton Not painted*
* Must be specied in the order.
IMPORTANT!
Down rating of pressure data and service life must be considered when using re resistant uid.
Hägglunds or its authorised representative must always be contacted for approval in the case of
these types of uids.
Environmentally acceptable uids
Fluid Approved Seals Internal paint
Vegetable */** Fluid HTG Yes Nitrile (std motor) –
Synthetic **/Esters HE Yes Nitrile (std motor) –
* Vegetable uids give good lubrication and small change of viscosity with dierent temperature.
Vegetable uids must be controlled every 3 months and temperature shall be less than +45 °C
(113 °F) to give good service life for the uid.
** Environmental acceptable uid gives the same service life for the drive, as mineral oil.
Filtration
The oil in a hydraulic system must always be ltered and also the oil from your
supplier has to be ltered when adding it to the system. The grade of ltration in a
hyd raulic system is a question of service life v.s. money spent on ltration.
In order to obtain stated service life it is important to follow our recommendations
concerning contamination level.