50/68 Installation
Bosch Rexroth Mellansel AB, Intallation and maintenance manual, Hägglunds VI, RE 15310-WA/10.2015
3.2.1 Oil connections, V46-C
S
D
S
D
D
C
D
A
2
1
m
P
D
C
2
12
m
m
MM C
P
A
Fig. 62:
Port Description Dimension Remarks
P* Main connection 1 1/2”
If P is used as inlet, motor rotates in
direction of the arrow
C* Main connection 1 1/2”
If C is used as inlet, the motor rotates in
opposite direction of the arrow
D Drain connection BSP 3/4”
M
1
Charge pressure conn. BSP 3/4”
M
2
Charge pressure conn. BSP 3/4”
Plugged, used as additional charging
port
S
D
Pilot pressure conn. BSP 1/2” Plugged
S
A
Pilot pressure conn. BSP 1/2”
12 bar (170 psi). 6 bar (85 psi) for valve
operating at no ow
P Pressure point conn. BSP 1/2”
A
m
, C
m
Pressure point conn. BSP 3/4”
C
m
Pressure point conn. BSP 1/2”
D
2
Ext. ushing conn. BSP 3/4” Note: Not marked on valve
* SAE-connection J518 C, code 62, 414 bar (6000 psi).