22/68 Installation
Bosch Rexroth Mellansel AB, Intallation and maintenance manual, Hägglunds VI, RE 15310-WA/10.2015
Fig. 20: Mounting of torque arm on pivoted attachment
DANGER ZONE
In case of failure of
torque arm installation
Fig. 21:
Removal of the torque arm for series 44 and 64
Use a suitable puller to pull o the torque arm. The puller holes are shown in the
gure 22.
Notice! If the torque arm is dicult to pull o, its hub may be cautiously heated.
TAC 1000-K
2 holes M16 x 40 mm (1.6 in)
Fig. 22: Puller holes on TAC 1000-K
DANGER
Make sure that the foundation can withstand the for ces from the torque arm.
WARNING
Before starting the motor, check that the rotating motor case can not cause damage.