EasyManua.ls Logo

Bosch rexroth KSM02.1B-061C-35N-M1-HP0-ET-NN-D7-NN-FW - 5.4.2 KCU02 data sheet; KCU data sheet - Currents, voltages, power

Bosch rexroth KSM02.1B-061C-35N-M1-HP0-ET-NN-D7-NN-FW
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.4.2 KCU02 data sheet
KCU data sheet - Currents, voltages, power
Description Symbol Unit KCU02.2N-ET-ET*-025-NN-N-NN-NW
Listing in accordance with UL
standard
UL 508C
Listing in accordance with CSA
standard
C22.2 No. 274-13
UL files E134201
Mass m kg 3.80
Degree of protection according to
IEC60529
IP20
Minimum distance on the top of
the device
1)
d
top
mm 80
Minimum distance on the bottom
of the device
2)
d
bot
mm 110
Horizontal spacing at the device
3)
d
hor
mm 0
Temperature increase with
minimum distances d
bot
; d
top
; P
BD
ΔT K < 60
Cooling type Forced
Volumetric capacity of forced
cooling
V
m
3
/h
approx. 0.3
Power dissipation at continuous
current and continuous DC bus
power respectively
P
Diss_cont
W 90
Insulation resistance at 500 V DC
R
is
Mohm > 50
Average sound pressure level
(accuracy class 2) at P
DC_cont
4)
L
P
dB (A) < 70
Control voltage data - input
Control voltage input
5)
U
N3
V DC 24 ±20 %
Rated power consumption control
voltage input at U
N3
P
N3
W 675
Max. inrush current at 24 V supply
I
EIN3_max
A 10.00
Pulse width of I
EIN3
t
EIN3Lade
ms < 1000
Input capacitance
C
N3
mF 11.00
Maximum allowed voltage for
1 ms
U
N3_max
V 33.00
Control voltage data - output
Nominal voltage
U
out
V 42.0
Nominal power
P
out
W 588.0
Latest amendment: 2017-01-20*
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
87/407
Technical data of the components
R911335703_Edition 04 Bosch Rexroth AG

Table of Contents