Data: Outputs
Data Unit min. typ. max.
Output voltage ON (with external supply) V U
ext
- 0.5 24 U
ext
Output voltage ON (without external
supply)
V 19.2 21 28.8
Output voltage OFF V n.s. n.s. 2.1
Output current OFF mA n.s. n.s. 0.05
Allowed output current per output (with
external supply)
mA n.s. n.s. 500
Allowed output current total or per group
(with external supply)
mA n.s. n.s. 1000
Allowed output current per output (without
external supply)
mA n.s. n.s. 100
Allowed output current total or per group
(without external supply)
mA n.s. n.s. 100
Update interval ns Depending on firmware
Short circuit protection Present
Overload protection Present
Allowed energy content of connected
inductive loads, e.g. relay coils; only
allowed as single pulse
mJ n.s. n.s. 400
Tab. 6-20: Digital outputs
The digital outputs have been realized with high-side switches.
This means that these outputs only can actively supply current.
The energy absorption capacity of the outputs is used to limit
voltage peaks caused when inductive loads are switched off. Limit
voltage peaks by using free-wheeling diodes directly at the relay
coil.