20/48 Bosch Rexroth AG VT-HNC100...3X | RE 30139-B/12.14
Assembly
6 Assembly
NOTE
Risk of short circuit!
Water may condense within the housing!
f Let the VT-HNC100...3X acclimate itself for several hours, as otherwise
water may condense in the housing.
The housing of the VT-HNC100...3X/ is perforated. According to the existing
protection class, dirt and fluids may easily enter and cause failures and a short
circuit! Safe functioning of the VT-HNC100...3X/ is thus no longer ensured.
f When working on the VT-HNC100...3X you must make sure that everything
is clean and that no fluids will enter the housing.
Major potential differences!
Danger of destroying the VT-HNC100...3X by connecting or disconnecting plugs
under voltage.
f Switch off power supply to the relevant system component before assembling
the unit or when connecting and disconnecting plug-in connectors.
6.1 Installation conditions
f For installing the product always observe the ambient conditions specified in
the data sheet RE 30139.
NOTE: The environment must be free from electrically conductive contamination
(acids, bases, corrosive agents, salts, metal vapors, etc.) and the device must not
be exposed to these substances. Rule out any deposits according to protection
class IP 20.
The VT-HNC100...3X is intended for top hat rail assembly in the control cabinet.
The dimensions of each version are listed in the data sheet RE 30139.
f Before commissioning, make sure that all the seals and plug of the plug-in
connection are installed correctly to ensure that they are leakproof and fluids
and contamination parts are prevented from penetrating the product.