Digital drive controller | VT-HNC100.../S 9/14
RE 30159, edition: 2012-03, Bosch Rexroth AG
Operating voltage
1)
U
B
18 to 30 VDC
Current consumption at 24 VDC CPU card approx. 200 mA
Per axis approx. 100 mA (observe additional current consumption
for connected sensors/actuators)
Processor 32 bit power PC
Analog inputs (AI) per axis electronics:
– Voltage inputs (differential inputs)
• Channel number 2
• Input voltage U
E
Max. +12 V to –12 V (+10 V to –10 V measurable)
• Input resistance R
E
200 k ± 5 %
• Resolution 5 mV
• Non-linearity < 0.2 %
• Calibration tolerance
2)
Max. 40 mV (with factory settings)
– Current inputs
• Channel number 2
• Input current I
E
4 mA to 20 mA
• Leakage current I
V
0.1 to 0.4 %
• Resolution 5 µA
– Voltage supply for analog sensors
via the VT-HNC100-1-3X/S U, I U
B
,
max. 200 mA at X2A, pin 14 (+24 Vsens)
Analog outputs (AO) per axis electronics:
3)
2
– Non-linearity
• In the range –9.5 V to +9.5 V < 0.1 %
• In the range –10 V to –9.5 V and +9.5 V to +10 V < 0.2 %
– Voltage output
• Output voltage U
nom
–10 V to +10 V (max. –10.7 V to +10.7 V)
• Output current I
max
±10 mA
• Load R
min
1 k
• Residual ripple ±60 mV (without noise)
• Resolution 1.25 mV
– Current output
• Output current standardized I
nom
4 mA to 20 mA
• Load R
max
500
• Resolution 0.625 A
Bus interface sercos III
Switching inputs (DI) and/or outputs (DO) per
axis electronics (adjustable via software) Quantity 11
Switching inputs (DI) Logic level log 0 (low) ≤ 5 V; log 1 (high) ≥ 10 V to U
B
,
I
e
= 20 mA with U
B
= 24 V
Connection Flexible conductor up to 1.5 mm
2
Switching outputs (DO) Logic level log 0 (low) ≤ 2 V; log 1 (high) ≤ U
B
; I
max
= 20 mA,
maximum load capacity C = 0.047 µF
Connection Flexible conductor up to 1.5 mm
2
Reference potential for all signals DGND
Technical data VT-HNC100-1-3X/S (1-axis version)
1)
If a 24 V transducer supply is implemented directly via the
VT-HNC100-1-3X/S (supply voltage is looped in), the transducer
specification has to be observed.
2)
If the factory settings are insufficient, the measurement technol-
ogy can be calibrated on site via software in a system-specific way.
3)
Configurable as current or voltage output.