10/14 VT-HNC100.../S | Digital drive controller
Bosch Rexroth AG, RE 30159, edition: 2012-03
Digital position transducers (encoder)
per axis electronics:
Position transducer, incremental
(transducer with TTL output)
Input voltage log 0 0 to 1 V
log 1 2.8 to 5.5 V
Input current log 0 –0.8 mA (with 0 V)
log 1 0.8 mA (with 5 V)
Max. frequency referring to Ua1 f
max
250 kHz
Voltage supply via the VT-HNC100...3X/S U, I 5.25 V ±1 %,
max. 400 mA at X8M1, pin 12 (+5 Venc)
– SSI transducer (Due to the higher control quality, an SSI transducer
with clock synchronization should be used.)
Coding Gray-Code / binary code
Data width Adjustable 12 to 28 bits
Line receiver / line driver RS485
Voltage supply via the
VT-HNC100...3X/S U, I U
B
,
max. 500 mA at X8M1, pin 14 (+24 Venc)
Position transducer, EnDat 2.2
Interface (clock and data) according to RS 485
Voltage supply via the VT-HNC100...3X/S U, I 5.25 V ±1 %,
max. 400 mA at X8M1, pin 12 (+5 Venc)
3.6 to 5.25 V must be applied to the transducer.
Resolution Minimum 10 nm or higher
Analog position transducer (encoder):
Input voltage U
E
Max. +12 V to –12 V (+10 V to –10 V measurable)
Input resistance R
E
> 10 M
Resolution 5 mV
Non-linearity < 0.2 %
Calibration tolerance
1)
Max. 40 mV (with factory settings)
Voltage supply via the VT-HNC100...3X/S U, I +10 V ± 25 mV, max. 20 mA at X8M1, pin 13 (+10 Vref)
Reference potential for all signals EGND
Dimensions See page 13
Assembly Top hat rail TH 35-7.5 or TH 35-15 according to EN 60715
Admissible operating temperature range
0 to 50 °C
Storage temperature range
–20 to +70 °C
Protection class according to EN 60529:1991 IP 20
Weight m 585 g
CE conformity See page 2
Further technical details upon request.
Technical data VT-HNC100-...-3X (1-axis version), continued
Notice:
For information on the environment simulation testing for the areas EMC (electro-magnetic compatibility), climate and
mechanical load, see data sheet 30139-U.
1)
If the factory settings are insufficient, the measurement
technology can be calibrated on site via software in a system-
specific way.

Related product manuals