8 | Product details
Gaz 6000 W8 716 473 216 (2014/09)
2.9 Technical data
WBN 6000-30
Unit NG LPG
Max. rated heat output (P
max
) 80/60 °C kW 30 30
Max. rated heat input (Q
max
), central heating kW 33.2 33.2
Min. rated heat output (P
min
) 53/47 °C kW 99
Min. rated heat input (Q
min
), central heating kW 10.2 10.2
Gas supply rate
Natural gas type H (H
i(15 °C)
= 9.5 kWh/m
3
) MJ/hr 132.8 –
Butane/propane (H
i
= 12.9 kWh/kg) MJ/hr – 132.8
Permissible gas supply pressure
NG Kpa 1.13 –
LPG Kpa – 2.75
Expansion vessel
Pre-charge pressure bar 0,5 0,5
Total capacity L 88
Calculation values for calculating cross-section to EN 13384
Flue gas temperature 80/60 °C max. rated °C 145 145
Flue gas temperature 80/60 °C min. rated °C 73 73
Flue gas mass flow rate, max. rated g/s 13.6 13.5
Flue gas mass flow rate, min. rated g/s 10,3 10,4
CO
2
at max. rated output % 5.5 – 6.0 5.6 – 7.0
CO
2
at min. rated output % 2.0 – 2.5 2.3 – 2.8
Flue gas rating group to G 636/G 635 G
61
/G
62
G
61
/G
62
NO
x
content mg/kWh 132 132
NO
x
class 33
Flue gas connection 60/100 60/100
General data
Power supply voltage AC ... V 240 240
Frequency Hz 50 50
Max. power consumption (central heating mode) W <130 <130
Standby power consumption W 22
Noise output level dB(A) 38 38
Max. flow temperature °C 40 – 82 40 – 82
Max. permissible operating pressure (P
MS
) heating bar 33
Permissible ambient temperature °C 0 – 50 0 – 50
Nominal capacity of appliance heating l 1,6 1,6
Weight (excl. packaging) kg 42 42
Dimensions, W x H x D mm 440 x 898x 315 440 x 898x 315
Table 4