10mm0
-
min. 5 mm
WALL MOUNTING
PLATE
FLUE
OPENING
-...:
' -
:;~-=---
'
hdeAf
0
!
I
'
I
'
I
'
I
'
OJ
~
0
6
720
611927-04.10
0
WALL MOUNTING
PLATE
FLUE
OPENING
CAUTION:
Ensure
there
are
no
pipes,
elec-
tric
cables,
damp
proof
courses
or
other
hazards
before
drilling.
SAFETY:
All relevant
safety precautions must be under-
taken. Protective clothing, footwear, gloves and
safety
goggles must be worn as appropriate.
FIXING
THE
POSITION
OF
THE
WALL
MOUNTING
PLATE:
The diagram opposite shows the relative
positions
of
the flue and the fixing
of
the wall
mounting plate, the mounting plate and pre-
plumbing manifold.
~
Place the wall mounting plate against the
wall
in
the desired position.
~
Mark 3 fixing points through the holes
(A,
B,
C)
in
the wall mounting plate.
~
Drill the 3 holes for wall mounting plate, wall
hanging bracket and pre-plumbing manifold.
~
Secure wall mounting plate with hanging
bracket with 3 screws (supplied with the
boiler). Do not fully fasten the lower 2
screws.
~
Use the horizontal slots
in
the wall mounting
plate to level the hanging bracket, mark the
4th
hole and drill.
~
Fix
and secure the hanging bracket with
both screws.
FLUE
OUTLET
~
Follow the diagram opposite to mark the
centre
of
the flue for rear outlet
(1,
& 2) or
for side
outlet
(2
& 3).
**
Note: increase this height by
52
mm for
every
1000
mm
of
horizontal length that the
flue outlet is away from the boiler.
~
For the
60/100
mm 0 flue make a 125
mm
diameter hole through the wall using a core
drill or similar.
For flues using
an
optional weather collar,
fitted from inside the building make a
150 mm
0 hole.
~
Clear away any debris.
FIXING THE
PRE-PLUMBING
MANIFOLD:
~
Mount the pre-plumbing manifold on the 2
lower screws and secure the screws.
INSTALLATION & SERVICING INSTRUCTIONS
FOR
WORCESTER BOSCH GREENSTAR
25CDI/30CDI/37CDI/42
co;
~ORCESTER
6 720
613
700a
(2006/11)
Bosch Group