INSTALLATION
85mm
·-·-'-·
II
![9
6720611927-06.1 0
FLUE
INSTALLATION
HORIZONTAL
FLUE
(60/100
mm
diameter)
For vertical flues
and
80/125 mm horizontal flues,
please refer to separate Flue Kit instructions.
NOTE: to ease the assembly
of
flue components,
apply silicone lubricant to sealing surfaces.
The
instructions for the 60/100 mm diameter flue
are shown below.
MEASURING
THE FLUE (Standard Flue):
~
Measure from the outside wall
to
the centre
line
of
the flue turret (length
L).
~
Subtract
52
mm from the length L
to
give
the
correct
dimension to the flue
elbow
con-
nection.
~
The terminal section should be
cut
to
this
dimension, however it must not be shorter
than
250
mm.
~
After cutting the end must be square and
free from burrs
to
prevent damage to the
flue seals.