EasyManua.ls Logo

Bosch Worcester Greenstar Ri ErP + Series - Malfunction or Failure; Initial Checks and Support

Bosch Worcester Greenstar Ri ErP + Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPLIANCE INFORMATION
6 720 821 670 (2018/06) 13
3.5 Internal wiring diagram
Fig. 2 Electrical diagram
[1] Air pressure switch
[2] Fan (fan wiring: Live = purple wire, Neutral = brown wire
[3] Flue overheat thermostat
[4] Flow temperature sensor (NTC)
[5] Flame sense electrode
[6] Spark electrodes
[7] Overheat thermostat
[8] External pump
[9] PCB
[10] External wiring center/junction box
[11] Earth bar connection
[12] Gas valve
SPARK
TRANSFORMER
DIAGNOSTIC
INTERFACE
CODE
PLUG
MODE
SWITCH
Slow 2 A fuse,
AC 230 V
EMS
BUS
CH TEMPERATURE
CONTROL
ON/OFF
SWITCH
ST9
ST6
ST5
ST2
ST1
F1
230V~
Min
Max
Norm
LN LP NPLR
Earth
11
COMMON
230V MAINS
SUPPLY
SL
L
N
6720644744-27.3Wo
4
10
8
9
1
2
12
3
5
6
7
Colour sequence
Colour sequence
Green
Live
Neutral
Red
Blue
Violet
Orange
Pump Live
Pump Neutral
Switched Live
LN
LP
LRNP
Installer connections
Connection Function
ST1 230V supply to the appliance
Live input (L)
Neutral input (N)
ST2 External pump supply connections and Switched live
(Live Return) to the appliance
•Pump Live (LP)
Pump Neutral (NP)
Demand input (LR)
Earth Earth connection, appliance 230V supply
Earth connection, external pump supply