6 720 607 800 (2016/02)
Appliance specifications | 7
2.9 Technical data
Technical characteristics Symbols Units WT11
Power
1)
1) GPL: Butane 45.65 MJ/kg (12.7 kWh/kg) – Propane 46.34 MJ/kg (12.9 kWh/kg)
Usable power Pn kW 19,3
Minimum usable power Pmin kW 7
Regulatory field 7 - 19,3
Nominal power Qn kW 21,8
Minimum nominal power Qmin kW 9
Gas data
Inlet pressure
G.P.L. (Butane/Propane) G30/G31 mbar 28-30/37
Consumption*
G.P.L. (Butane/Propane) G30/G31 kg/h 1,9
Gas connection 3/4”
Water data
Maximum admissible pressure
2)
2) In order to account for the dilation effect of water, it should not exceed this value.
pw bar 12
Minimum working pressure pwmin bar 0,3
Startup flow l/min 3,2
Flow corresponding to a temperature rise of 25 °C l/min 11
Water connection 3/4”
Smoke circuit
Combustion gas flow
3)
3) For nominal calorific power
kg/h 50
Temperature of gases at extractor grill
Using maximum possible drive compression (4 m) °C 170
Using minimum drive compression (0,37 m) °C 220
Flue socket dia. mm Ø60/100
Electrical circuit
Tension (50 HZ) V 230
Maximum power limit W65
Type of protection IPX4D
General Data
Weight (excluding packaging) kg 20
Height mm 670
Width mm 340
Depth mm 220
Table 5