83
This is an example of the PASSED ESP-88 chassis test data in Excel format.
5. Testing method and criteria.
Note: The information in the following pages is provided for reference only. You will not need to
set the ATS2 manually to perform these tests.
This section describes the settings and criteria of each of the tests to be performed.
The setting of the ATS-2 test station will be done automatically by the ATS2 Macro.
5-1. Gain at 0dB
ESP Setting: Set all channel gains to = 0dB. (Command on COM = ^BA{1/2}{L/R}00^C)
AMPL(1kHz)
ATS2 Settings
Test Limits
TEST PROCEDURES
Item Setting
Frequency 1kHz
Amplitude +4.00dBu
B/W <10HZ / FS/2
Filter None
Item Upper limit Lower limit
Level +5.5dBu +2.5dBu