EasyManua.ls Logo

Boss TPSE201 - User Manual

Boss TPSE201
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Instruction Manual
TPSE201 (181422) - BOSS
TM
Universal Programmer
TPSE101 (569565) - BOSS
TM
Universal Timeswitch
Thank you for purchasing this product. If installing for someone else, please ensure that the
instructions are handed to the householder.
Please read this manual prior to installation or use. Retain for future reference.
Always isolate the mains supply before removing the unit from the backplate.
Please leave these instructions with the end user where they should be kept in a safe place for
future reference
Installation
The TPSE201/TPSE101 is easily installed using the backplate supplied. This can be mounted directly to
the wall or a single gang recessed box using the holes provided; cable entry is from the rear.
Specification
Power supply 230V/50Hz
Switch rating 6(2)A
Switch type Single pole, double throw (SPDT)
Operating temperature 0°C - 50°C
Storage conditions -20°C - 60°C
Frost protection temperature 5°C
Programme
5/2, 7 day or daily selectable by jumper
3 setting per day
Time display 12 or 24 hour
Memory Internal memory back-up
Backlight Green LED
Switches/Jumpers
The installer should select the jumper positions required if changing from the factory pre-sets, these
jumpers are found on the rear of the unit. Always enable the internal memory back up battery before
installing the unit,
Switch/Jumpers Function
Program type
3x2 pins jumpers for 5+2 days (factory default setting),
7 days program or daily
P/G (TPSE201 only)
3x1 pin jumper for fully pumped and controlled system
(factory default setting) or gravity-fed hot water system.
Internal backup battery
3x1 pin jumper to enable/disable the internal backup
battery (disabled is the factory default setting)
Question and Answer IconNeed help?

Do you have a question about the Boss TPSE201 and is the answer not in the manual?

Summary

Installation

Specification

Switches;Jumpers

BackPlate & Wiring

TPSE101 Terminals

Terminal assignments and functions for the TPSE101 model.

TPSE201 Terminals

Terminal assignments and functions for the TPSE201 model.

Internal Wiring Diagrams

TPSE201 Wiring Diagrams

Wiring diagrams for TPSE201 in Y-Plan and S-Plan systems.

Alternative Thermostat Wiring

Wiring connections for other BOSST™ room thermostats.

TPSE101 Wiring Diagrams

Combi Boiler Connections

Wiring diagrams for connecting TPSE101 to a combi boiler.

Wired & Wireless Thermostat Wiring

Wiring configurations for wired and wireless thermostat connections.

Connection Types

Details for 230Vac and potential-free connection types.

User Instructions

Keyboard Functions

Explanation of the device's keyboard buttons and their functions.

Initial Power Up and Reset

Post-Reset Settings

Details on device settings after a reset operation.

Default Program Settings

Setting the Clock

Clock Format Selection

How to select between 12-hour and 24-hour clock formats.

Time and Date Adjustment

Procedure to adjust hour, minute, year, month, and day.

Day Light Saving

Programming - 5-2, 7 Day & Daily

Chronological Programming Rules

Rules and guidelines for programming events chronologically.

Program Review and Changes

How to review or change existing program settings.

7 Days Programmed Operation

Daily Week Programming

How to program independent settings for each day of the week.

Daily Programmed Operation

All-Day Time Settings

How to set up different time settings for all days.

Operating Mode Selection

Mode Cycling and Selection

How to cycle through and select operating modes: On, Once, Auto, Off.

Operating Mode Functions

Mode Descriptions

Explains the function of each available operating mode.

Temporary Override

Hr+ Program Override

How to activate and use the temporary override for programs.

Advance Override

Advance Override Activation

How to activate the advance override mode for programs.

Holiday Override

LCD Backlight

AC Monitoring

Backup Battery

Battery Replacement

Instructions for replacing the backup battery.

Control Patterns

Control Status Indication

Explanation of the LED output indicator status.

Summary

Installation

Specification

Switches;Jumpers

BackPlate & Wiring

TPSE101 Terminals

Terminal assignments and functions for the TPSE101 model.

TPSE201 Terminals

Terminal assignments and functions for the TPSE201 model.

Internal Wiring Diagrams

TPSE201 Wiring Diagrams

Wiring diagrams for TPSE201 in Y-Plan and S-Plan systems.

Alternative Thermostat Wiring

Wiring connections for other BOSST™ room thermostats.

TPSE101 Wiring Diagrams

Combi Boiler Connections

Wiring diagrams for connecting TPSE101 to a combi boiler.

Wired & Wireless Thermostat Wiring

Wiring configurations for wired and wireless thermostat connections.

Connection Types

Details for 230Vac and potential-free connection types.

User Instructions

Keyboard Functions

Explanation of the device's keyboard buttons and their functions.

Initial Power Up and Reset

Post-Reset Settings

Details on device settings after a reset operation.

Default Program Settings

Setting the Clock

Clock Format Selection

How to select between 12-hour and 24-hour clock formats.

Time and Date Adjustment

Procedure to adjust hour, minute, year, month, and day.

Day Light Saving

Programming - 5-2, 7 Day & Daily

Chronological Programming Rules

Rules and guidelines for programming events chronologically.

Program Review and Changes

How to review or change existing program settings.

7 Days Programmed Operation

Daily Week Programming

How to program independent settings for each day of the week.

Daily Programmed Operation

All-Day Time Settings

How to set up different time settings for all days.

Operating Mode Selection

Mode Cycling and Selection

How to cycle through and select operating modes: On, Once, Auto, Off.

Operating Mode Functions

Mode Descriptions

Explains the function of each available operating mode.

Temporary Override

Hr+ Program Override

How to activate and use the temporary override for programs.

Advance Override

Advance Override Activation

How to activate the advance override mode for programs.

Holiday Override

LCD Backlight

AC Monitoring

Backup Battery

Battery Replacement

Instructions for replacing the backup battery.

Control Patterns

Control Status Indication

Explanation of the LED output indicator status.

Boss TPSE201 Specifications

General IconGeneral
BrandBoss
ModelTPSE201
CategoryTimer
LanguageEnglish

Related product manuals