11. Generator option
41
Fig. 42
* Allow the engine to continue running for
about 2 minutes, so that the generator
cools down.
*
Stop the generator.
Efficiency at nominal output
at 0.8 ind 0.80
at 1.0 0.82
Distortion factor < 5%
Weight 53 kg
Overall size BG132
Overall length 357 mm
Generator regulator
Model LCAR3
Connector assignment
8 pole Pin Colour Function
1 red F1
2 grey F2
3
not assigned
4
yellow ZU
5 yellow ZV
6 yellow ZW
7 brown L1
8
blue N
11.7 Technical characteristics of
400/230V 5/8kVA GTS
generator
Generator model........ DWG 8/5-2-ZE
Generator type........... Synchronous,
internal pole,
electronically
controlled
Generator frame ........ B3/two bearings
Degree of protection .. IP 54
Generator characteristics:
Extremely low dynamic internal resistance,
same output voltage whether hot or cold,
no dangerous overvoltage during dynamic
overspeed, small reactive effect from non-
linear or very inductive equipment, trouble-
free operation of equipment with phase
control, no dangerous overvoltage of the
unloaded phases, load current may have
4-pole 1 black switch contact
significant DC components
11.6 Technical characteristics of
110V 6kVA GTS generator
Switchbox
2
black switch contact
3
not assigned
4
not assigned
Power system
(IEC 38/50Hz) 3-phase AC
400V/230V
Generator characteristics:
Extremely low dynamic internal resistance,
same output voltage whether hot or cold,
no dangerous overvoltage during dynamic
overspeed, small reactive effect from non-
linear or very inductive equipment, trouble-
free operation of equipment with phase
control, no dangerous overvoltage of the
unloaded phases, load current may have
significant DC components
Power system
(IEC 38/50Hz) 1-phase AC
2 x 115V
Amplified phases 3
Nominal output
(0.8 cap/ind) 7000VA
Nominal current 32A + 2 x 16A
Startup current 4.1 times I
rated
Operating mode S1, continuous
Protective measure Electrical isolation,
with equipotential
bonding conductor
in accordance with
VDE 0100.728
Coolant Air/externally
ventilated with own
fan, independent of
direction of rotation
Nominal speed for
nominal frequency 3000 rpm
Min. speed for
nominal output 3000 rpm
Degree of protection IP 54
Dimensions 250x204x135
Design Front panel type
Fusing All poles
U1 C32A
U2 2 x 16A
Insulation monitoring
Model GMW-RISO1.0
Controls Red test button
Areas of application
engines difficult to get running, welding
devices (incl. inverters), pumps,
compressors, tools, construction
machinery, illumination
Generator data
Winding
Colour
Ins. class
Resistance
(at 20°C)/
U1-N brown-blue F 0.165
U2
-
N
black
-
blue
F
0.165
W
-
N
black
-
blue
F
0.28
ZU-ZN yellow-yellow
F
2.5
ZV
-
ZN
yellow
-
yellow
F
2.5
ZW
-
ZN
yellow
-
yellow
F
2.5
1F1
-
1F2
red
-
grey
H
22.1
(All resistances measured using the 4-wire
R method)
Nominal output (0.8 cap/ind)
single-phase 5000VA
3-phase (sym) 8000VA
Nominal current
single-phase 21.6A
3-phase (sym) 11.5A
Startup current 4.1 times I
rated
Operating mode S1, continuous
Protective measure Electrical isolation,
with equipotential
bonding conductor
in accordance with
VDE 0100.728
Coolant Air/externally
ventilated with own
fan, independent of
direction of rotation
Nominal speed for
nominal frequency 3000 rpm
Min. speed for
nominal output 3000 rpm
Efficiency at nominal output
at 0.8 ind 0.80
at 1.0 0.82
Distortion factor < 5%
Weight 53 kg
Overall size BG132
Overall length 357 mm
Generator regulator
Model LCAR 3
Connector assignment
8 pole Pin Colour Function
1
red F1
2
grey F2
3
violet 1/2U
4
violet 1/2V
5
violet 1/2W
Generator model
WG 6,0
-
2ZE
Generator type
Synchronous,
internal pole,
electronically
Generator frame
controlled
B3/two bearings
Degree of protection
IP 54

Table of Contents