35
M21/M26/M30
35
8 Important Information 8
8.1 First Startup 8.1
The BÖWE Customer Service department is responsible for carrying out the first startup.
Attention: Before opening the switch panel or removing paneling,
set the main switch to "0".
8.1.1 Preparatory Work
Set up the supply systems (electrical current, cooling water, compressed air, steam and
condensate lines).
8.1.2 Filling Machine With Solvent
(Gas displacement procedure is mandatory)
707761-17-0
You must use solvents that have a flash point that is higher than the temperature stated on the
machine nameplate.
The amount of solvent needed is:
Machine M21 tank I: approx.110 l / 29.0 US gal
Machine M26 tank I: approx.135 l / 35.6 US gal
Machine M30 tank I: approx.155 l / 40.9 US gal
Total filling amount M21: approx. 445 l * / 117.5 US gal *
Total filling amount M26: approx. 510 l * / 134.6 US gal *
Total filling amount M30: approx. 565 l * / 149.2 US gal *
Attention: This solvent is a powerful fat solvent. Wear gloves when
handling solvent and apply protective skin ointment to hands when
done. Do not smoke.
Immediately change any clothing that is wet with solvent.
If you get solvent in your eyes,:
• rinse them thoroughly with water
• and see a doctor.
You must fill the pump with solvent before turning it on.
Check that the direction of rotation is correct.
* Machine with 1 economy filter.
For machines with 2 economy filters: + 50 l (13.2 US gal)
For machines with 2 economy filters and 1 cartridge filter: + 75 l (19.8 US gal)
For machines with 2 economy filters and 2 cartridge filters: + 90 l (23.8 US gal)