42
M21/M26/M30
42
9 Technical Specifications 9
Machine
Heating
M26
Steam
M30
Steam
Consumption for drying:
Drying time inc. reduction min. 31 36
Elec. energy drying kWh 3.6 4.1
Saturated steam drying kg (lb) 10.0 (22.0) 12.0 (26.5)
Cooling water dr.(12 °C/53.6 °F) l (US gal) 150 (39.6) 170 (44.9)
Consumption for distillation(1x at low
level):
Elec. energy distillation kWh 0.6 0.75
Saturated steam distillation kg (lb) 15 (33.1) 18 (39.7)
Cooling water for dist. (12 °C/53.6 °F) l (US gal) 220 (58.1) 260 (68.6)
Consumption per cycle: *
Elec. energy, total kWh 4.7 5.35
Saturated steam, total kg (lb) 25.0 (55.1) 30.0 (66.2)
Cooling water, total (12 °C(53.6°F) l (US gal) 370 (97.7) 430 (113.5)
Compressed air (6 bar/87 psi) l (US gal) 6 (1.6) 6 (1.6)