45
M21/M26/M30
45
10 Settings and Optimum Operating Values 10
Machine M21 M26 M30
Drying:
Cooling water regulator setting:
Adjust 4 – 6 min. after start of drying bar
(psi)
18
(261)
18
(261)
18
(261)
Thermal sensor cage entry * °C
(°F)
75
(167)
75
(167)
75
(167)
Temp. sensor after cooler:
Alarm value 1 °C
(°F)
Alarm value 2 °C
(°F)
Safety temperature limiter after cooler * °C
(°F)
45
(113)
45
(113)
45
(113)
Safety temperature limiter, cage inlet * °C
(°F)
100 (212)
100 (212) 100 (212)
Distillation
Cooling water regulator condenser °C
(°F)
45
(113)
45
(113)
45
(113)
Thermal sensor:
Cycle distillation OFF °C
(°F)
135 (275)
135 (275) 135 (275)
Still stripping OFF °C
(°F)
138 (280)
138 (280) 138 (280)
Residue draining °C
(°F)
55
(131)
55
(131)
55
(131)
Thermal sensor, distilled solvent °C
(°F)
55
(131)
55
(131)
55
(131)
Restrictor in steam feeder mm
(in)
6
(.24)
6
(.24)
6
(.24)
Restrictor in direct steam line mm
(in)
4
(.16)
4
(.16)
4
(.16)
Vacuum pressure control kPa minus 75 minus 75 minus 75