15
6 Operation 6
To fill without emissions, proceed as follows:
- Remove the screw cap on the pump line.
- Connect a hose between the barrel and pump suction side.
- Connect gas displacement line between the barrel and water separator.
- Open the ball valve.
- Start program P44.
- The tanks fill up, with one overflowing into the other.
- Watch the level of the liquid in the tanks and stop program P44 when the tanks are full.
- Close the ball valve.
- Remove the connecting lines to the barrel.
- Screw the cap back on to the pump line.
- Remove the gas displacement line.
With c and o combinations:
- First fill the c machine with P44
- Next start P61 on the o machine in order to fill it.
- Then start P44 on the c machine again.
6.1.3 Refilling Solvent
Follow the procedure given in Point 6.1.2 for routine refilling of solvent.
Attention: Even empty containers can still hold solvent residues.
Therefore tightly seal the container (barrel) again and
store or dispose of in accordance with regulations!
6.1.4 Filling the Slimsorba Carbon Container (Optional Equipment)
- Loosen the upper pipe flange on the carbon container.
- Loosen the quick release fastener on the cover and remove cover.
- Remove fine filter sieve and clamping ring.
- Fill in 12 kg (22 lb) of activated carbon (cylindrical pellets with approx. 4 mm (0.16 inch) diameter,
type Supersorbon K40). The heating coil must be covered.
- Replace the fine filter sieve and clamping ring.
- Replace the cover and close the quick release fastener.
- Secure the upper tube of the carbon container again.
P25/P30