44
11 Maintenance 11
Disposing of the machine
- Drain filters
- Remove, clean and dry filter discs
- Drain water and safety separator or process water tank.
Dispose of process water and rack solvent.
- Empty tanks. You can draw off the solvent residue by tilting the machine and attaching
one end of a flexible suction tube to an external pump and inserting the other end
through the sight-glass opening.
- Empty condenser.
- Empty out solvent and sludge pumps.
Do not leave any solvent residue in the base of the pump.
- Empty and clean the still, dispose of residues.
- Pump cooling agent out of the refrigeration unit
(done by authorized customer service technician).
- On machines with Slimsorba, remove carbon from the Slimsorba and
dispose of in special waste.
- Close open solvent lines tightly when disassembling the machine.
- You must completely remove all residues that could present a hazard to people and the
environment.
Observe safety regulations concerning the handling of solvent (see Point 2).