Power on Utilities
There are six power-on utilities to set up and test printer hardware. These utilities are
activated by pressing FEED, then turning on the printer power simultaneously and
releasing
the button at a different LED color.
Follow these steps for various power-on utilities:
1.
Turn off the power switch.
2.
Hold the Feed button down, then turn the power switch ON.
3.
Release the button when LED indicates a color for a different function.
Power on Utilities
LED color changes as follows:
LED Color
Amber
Red
(5 blinks)
Amber
(5 blinks)
Green
(5 blinks)
Green/Amber
(5 blinks)
Red/Amber
(5 blinks)
Solid
green
Functions
1. Ribbon Sensor Calibration
and Gap / black mark
sensor calibration
Release
2. Gap / black mark sensor
calibration, Self-test and
enter dump mode
Release
3. Printer initialization
Release
4. Set black mark sensor as
media sensor and
calibrate the black
mark
sensor
Release
5. Set gap sensor as media
sensor and calibrate the
gap sensor
Release
6. Skip AUTO.BAS
Release