EasyManua.ls Logo

Brain Bee 9000 Bus Plus - Page 65

Brain Bee 9000 Bus Plus
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH 65 / 73 CAP. 16 - MESSAGE AND ALARM CODES
9000 BUS
PLUS
CODE MESSAGE When it occurs Possible
situations
Actions
W036 FURTHER OIL
INJECTION NOT
POSSIBLE
During oil
injection phase
Insufficient
vacuum level
Increase the vacuum
phase time, check the
A/C system tightness.
W044 VESSEL EMPTY During flushing
or Tank
refrigerant
internal re cycling
phase
Gas level is too
low for the
procedure to be
completed
Fill the internal tank with
gas
W045 LP VERY LOW,
CHECK CIRCUIT
BEFORE
CONTINUING
During flushing
phase
LP hose
disconnected,
flushing
couplings not
properly
connected or
leak in circuit
being flushed.
Reconnect LP and/or the
fittings and eliminate any
leaks.
W047 POSSIBLE LEAKAGEDuring the
refrigerant
recovery phase
Vehicle A/C
system may
have leaks
--

Table of Contents