CAP. 16 - MESSAGE AND ALARM CODES 66 / 73 ENGLISH
9000 BUS PLUS
Alarm messages are coded Axxx in the window title bar.
Alarms immediately terminate the procedure and prevent its resumption.
CODE MESSAGE When it can
occur
Possible causes Actions
A000 EEPROM NOT
WORKING
Electronics
fault
EEPROM
damaged
Replace the logic electronic
board
A001 EEPROM DATA
CORRUPT
Electronics
fault
EEPROM
damaged
Replace the logic electronic
board
A002 PRESSURE SAFETY
SWITCH
ACTIVATED
Pressure
above 18 bar
High pressure in
the internal tank
or circuit
between
compressor and
tank obstructed
or closed.
Verify
If internal vessel
pressure level is over 18
bar, wait for pressure
reduction
disconnect
equipment from the mains,
use safety protection, open
equipment and verify if the
valve between compressor
and internal vessel are
open
A003 ADC NOT
WORKING
Electronics
fault
ADC analog-
digital converter
damaged
Replace the logic electronic
board.
A032 CIRCUIT STILL
UNDER PRESSURE
During the
vacuum,
vessel filling
or leak test
phase in
vacuum
The vehicle A/C
system is
pressurized
Recover the refrigerant gas
from the vehicle before
starting another vacuum
phase.

Table of Contents