36
21 Year SET YEAR 2000 2000
22 Change Temperature Units UNITS
TEMPERATURE
°C
or
°F Depending on
version
23 Change Altitude Units UNITS ALTITUDE METER
or
FEET
Depending on
version
24 Change Air Pressure Units UNITS AIR
PRESSURE
HPA
or
INHG
Depending on
version
25 Change Fuel Units UNITS FUEL LITERS
or
USGAL
Depending on
version
26 Change Oil Pressure Units UNITS OIL
PRESSURE
BAR
or
PSI Depending on
version
27 RPM Sensor Filter RPM SENSOR MODE
ROTAX
or
SPARK
ROTAX (*)
28 4*EGT Mode 4*EGT SCROLL
MODE OR
2*EGT+2*CHT
MODE
4EGT
or
2C+2E
2C+2E (*)
29 Type of Oil Pressure Sender OIL PRESSURE
SENSOR
DIGI
(switch) or
ANA
(analogue
sender)
ANA
30 Password Function USE SECURITY
CODE
OFF
or
NOPWR
or
ON
NO
31 Pt100 WaterTemp Port on/off USE WATER TEMP
PORT
YES / NO YES (*)
32 Pt 100 Oil Temp Port on/off USE OIL TEMP
PORT
YES / NO YES (*)
33 EGT 1 (Type K) Port on/off USE EGT 1 PORT YES / NO YES (*)
34 EGT 2 (Type K) Port on/off USE EGT 2 PORT YES / NO YES (*)
35 CHT 1 (Type K) on/off USE CHT 1 PORT YES / NO YES (*)
36 CHT 2 (Type K) on/off USE CHT 2 PORT YES / NO YES (*)
37 Fuel Flow sensor Port on/off USE FUEL PORT YES / NO YES
38 Type of fuel system (single or
flow-back)
FUEL FLOW MODE 1WAY
or
2WAY or no
fuel port
used
1WAY (*)
39 Firmware Version SOFTWARE
VERSION
Numerical (no setting
possible)
40 Serial Number SERIAL NUMBER Numerical (no setting
possible)
41 Reset to Factory Settings RESTORE FACTORY
SETTINGS
SURE?
(*) These values are reset when a RESTORE FACTORY SETTINGS is performed.
(#) These functions can be locked by the aircraft manufacturer
Note: All values shown above are just examples and may not be correct for
your type of aircraft or engine.

Table of Contents