SEC.20 BASIC TROUBLESHOOTING
3. Frost Buildup on Evaporator Fins
• Allow the freezer and refrigerator to thaw.
Refrain from overloading the provided area.
Airflow and circulation are vital for proper
cooling and to prevent frost buildup.
If issue persists, please contact your
Dealer to inspect and repair as needed.
L. RUNNING LIGHTS
1. Running Lights Not Operating
Check the fuse to ensure it is not blown.
Check wiring connections.
Replace the light as needed.
If issue persists, please contact your
Dealer to inspect and repair as needed.
M. SLIDE-OUT
1. Runs In and Out Slowly, Binds,
and/or Squeaks
Ensure sucient power is supplied.
Lubricate slide-out rollers and gear
pack (through frame slides only)
with dry silicone spray lubricant.
If issue persists, discontinue the use of the
slide-outs and contact your Dealer to inspect
and repair as needed.
2. Water in Entering at the Rear Corners
Verify that the exterior seals are making
proper contact with the slide-out box.
Seals may be flipped in the wrong direction.
Ensure the seals are clean and free of
any obstructions, dirt, or debris.
Make sure the weep hole found in the
ramp pan is clean and unobstructed.
If issue persists, please contact your
Dealer to inspect and repair as needed.
3. Room Will Not Move In or Out
Ensure there is sucient power source.
Verify battery voltage and recharged
as needed.
Check the auto-resetting mini-breaker
located in the front fifth wheel bulkhead
compartment. See the manufacturer’s manual
for additional information.
If issue persists, please contact your
Dealer to inspect and repair as needed.
N. TERMINATION VALVE
Leak at Termination Valve
Ensure debris is not seated within valve.
Replace valve as needed.
If issue persists, please contact your
Dealer to inspect and repair as needed.
O. TV ANTENNA
Poor TV Reception
Check that the Antenna Power is ON.
Note that it is located in the ceiling
behind the bedroom TV.
Check the connections at both
the TV and wall plate.
If issue persists, please contact your
Dealer to inspect and repair as needed.
P. WASTE TANK
Waste Tank (Black) Will Not Properly Drain
Check for debris or buildup within the tank
and clean as needed. To prevent buildup: