EasyManua.ls Logo

Brooks 5850 S - User Manual

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(217) 352-9330 | sales@artisantg.com | artisantg.com
-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your
definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
Critical
and
expedited
services
Leasing
/
Rentals/
Demos
In
stock/
Ready-to-ship
!TAR-certified
secure
asset
solutions
Expert
team
I
Trust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Brooks Instrument 5851S at our website: Click HERE

Questions and Answers

  • T
    timothythomasAug 12, 2025
    What to do if the output signal stays at 5.25 Vdc in Brooks 5850 S Measuring Instruments?
    • S
      samantha23Aug 12, 2025
      If the output signal of your Brooks Measuring Instruments stays at approximately 5.25 Vdc or 21 mA, even when there is flow and regardless of the set point, it could be due to a few reasons. It might be that the valve is leaking or stuck open, in which case you should clean and/or adjust the control valve. Another possibility is that +15V is applied to the valve override input; check the valve override terminal (pin 12). Finally, a defective electronic board could also be the cause.
  • J
    Julia KeithAug 15, 2025
    Why is my Brooks Measuring Instruments controller oscillating?
    • W
      whansenAug 16, 2025
      If the controller oscillates in your Brooks Measuring Instruments, this could be due to several factors. The pressure drop or inlet pressure might be deviating from calibrated values, so you should adjust the pressures. It's also possible that the orifice is oversized, so check the orifice size. Another cause might be that the valve is out of adjustment, so adjust the valve. Unstable inlet pressure may also cause oscillations.
  • M
    matthew27Aug 19, 2025
    What to do if Brooks 5850 S Measuring Instruments output signal won't go below 2%?
    • J
      jaydavidsonAug 20, 2025
      If the output signal of your Brooks Measuring Instruments follows the set point at higher settings but doesn't go below 2%, the control valve may be leaking or stuck open. To resolve this, clean the control valve.
  • R
    rmilesAug 23, 2025
    Why Brooks 5850 S output signal does not reach full scale?
    • R
      Robin TylerAug 23, 2025
      If the output signal follows the set point at lower settings but doesn't reach full scale on your Brooks Measuring Instruments, it could be due to several reasons. You might have insufficient inlet pressure or pressure drop, so adjust the pressures and inspect in-line filters, cleaning or replacing them as needed. Another possibility is a partially clogged sensor, in which case you should clean the sensor. If you have MFC, the valve could be partially clogged, so clean the control valve. Also if you have MFC, the valve might be out of adjustment, so adjust the valve. Finally, in MFC, valve guide spring failure may be the cause.
  • J
    jackleonardAug 27, 2025
    What to do if flow cannot be achieved in Brooks Measuring Instruments?
    • S
      Steven JonesAug 27, 2025
      If the flow cannot be achieved regardless of the set point in your Brooks Measuring Instruments, especially in a Mass Flow Controller (MFC), there are a few potential causes. The control valve might be clogged, so clean the control valve. Another possibility is that the valve override input is grounded, so check the valve override input (pin 12).
  • J
    John WebbAug 31, 2025
    Why the output stays at zero in Brooks 5850 S Measuring Instruments?
    • E
      Erin KimAug 31, 2025
      If the output of your Brooks Measuring Instruments stays at zero regardless of the set point, even when there is flow, a possible cause is a clogged sensor. In this case, clean the sensor. Another reason may be a defective electronic board.
  • C
    Charles HernandezSep 3, 2025
    How to fix calibration issues in Brooks 5850 S when flow is too high?
    • J
      Jacob PughSep 4, 2025
      If your Brooks Measuring Instruments is grossly out of calibration and the flow is higher than desired, it could be due to a partially clogged sensor. To fix this, clean the sensor.
  • C
    Catherine WalkerSep 7, 2025
    What causes low flow in Brooks 5850 S Measuring Instruments?
    • J
      Justin CookSep 7, 2025
      If your Brooks Measuring Instruments is grossly out of calibration and the flow is lower than desired, it might be due to a partially clogged restrictor. To resolve this, replace or clean the restrictor.

Summary

Essential Instructions

Pressure Equipment Directive (PED)

Details compliance with the European Pressure Equipment Directive.

ESD (Electrostatic Discharge)

Outlines precautions for handling electronic components sensitive to static electricity.

Section 1 Introduction

Alarms

Details the various alarm types and conditions for the instruments.

Section 2 Installation

Mechanical Installation

Provides recommendations for mounting position and handling during mechanical installation.

Electrical Interfacing

Details the 15-pin Sub-D connector pin assignments for electrical connections.

2.9 Digital Communication Setup

Describes the setup of digital communication via piggyback boards and dipswitches.

Section 3 Operation

3.1 Operating Procedure

Step-by-step guide for powering up and starting normal operation.

3.3 Calibration Procedure

Describes the requirements and methods for instrument calibration.

Section 4 Maintenance

Troubleshooting and System Checks

Guidance on diagnosing and resolving system issues before bench troubleshooting.

Bench Troubleshooting

Detailed steps for troubleshooting the instrument on a workbench.

Troubleshooting Table

Lists common troubles, their possible causes, and corrective actions.

Calibration Procedure

Details calibration requirements and Brooks' Vol-U-Meter equipment.

Section 5 Specification

Performance Specifications

Details accuracy, repeatability, rangeability, and stability specifications.

Appendix A: Gas Conversion Tables

Appendix B: Dimensional Drawings

Appendix D: Important Safety Instructions

Appendix E: Modellist

Brooks 5850 S Specifications

General IconGeneral
TypeMass Flow Controller
Operating PressureUp to 150 psig
Gas CompatibilityCompatible with a wide range of gases
Accuracy±1% of full scale
Operating Temperature0 to 50°C
Process Connection1/4"
Communication ProtocolAnalog (0-5 VDC, 4-20 mA)
DimensionsVaries by model
WeightVaries by model