Error code 0506
The center thermistor of the fuser unit detected a temperature fall greater than the specified 
value within the specified time.
Print Unable 05
Turn the power off and then back on again.
<User Check>
• Turn OFF the power switch. After several seconds, turn ON the power again and check 
that this error is reset.
Step Cause Remedy
1
Connection failure of the center 
or side thermistor harness of the 
fuser unit
Reconnect the center or side thermistor 
harness of the fuser unit.
2
Connection failure of the fuser 
unit heater harness
Reconnect the fuser unit heater harness.
3
Connection failure of the eject 
sensor PCB flat cable
Reconnect the eject sensor PCB flat cable.
4
Connection failure of the LVPS 
harness
Reconnect the LVPS harness.
5
Eject sensor PCB failure Replace the eject sensor PCB ASSY.
6
Fuser unit failure Replace the fuser unit.
7
Low-voltage power supply PCB 
failure
Replace the low-voltage power supply PCB 
ASSY.
8
Main PCB failure Replace the main PCB ASSY.