MONITORING SYSTEM
PILOT
LAMP(S)
ON
BEEPER
MESSAGE
DISPLAY
DESCRIPTION
4short
beeps
every
5
minutes
REV LIMIT
Engine RPM limited for protection when
certain faults occur.
——
OVER REV
On E-TEC engines, indicates that maximum
engine RPM is reached. Check clutch
calibration.
Short
beeps
repeating
rapidly
SHUTDOWN
Shutdown proced ure in force due to engine
overheating or fuel pump problem, remove
tether cord cap from engine cut-off switch
and contact an authorized Lynx dealer.
——
COMMUNICATION
Communication problem between ECM
and gauge. S top engine, remove tether
cord cap . Wait a few minutes, then start
engine. If problem persists, contact an
authorized Lynx dealer.
2short
beeps
Good ke y, vehicle re ady to operate.
2short
beeps,
repeating
slowly
CHECK KEY
Unable to read key (bad connection). Make
sure the key is clean and correctly snapped
on post.
D.E.S.S.
Short
beeps
repeating
rapidly
BAD KEY
Invalid key or key not program med. Use
the proper key for the vehicle or have the
programmed.
——
(blinking)
Fuel level sensor problem.
——
THROTTLE OPEN
Throttle lever app lied while attempting an
engine start (engine cranks but won't run).
Release throttle while starting.
——
DROWN MODE
Throttle lever wide open while attempting
an e ngine start (engine cranks but won't
run). Release throttle while starting.